AC Hotel 80 Queen Street East

HISTORICAL
Drawings Specs All
M Mech 4
[M-302] 75Ø DCW
[M-303] 50Ø DHW
[M-301] CONTINUATION
[M-305] 65Ø NPW
P Plumb 1
[P-14] 841 x 1189 ISO A0 SHEET SIZE
E Elec 22
[E-1.0] ELECTRICAL LEGEND AND DETAILS
[E-1.1] ELECTRICAL DETAILS
[E-2.2] ELECTRICAL PLAN -
[E-2.3] ELECTRICAL PLAN -
[E-2.4] ELECTRICAL PLAN -
[E-2.5] ELECTRICAL PLAN -
[E-2.6] ELECTRICAL PLAN -
[E-3.2] REFLECTED CEILING PLAN -
[E-3.3] REFLECTED CEILING PLAN -
[E-3.4] REFLECTED CEILING PLAN -
[E-3.6] REFLECTED CEILING PLAN -
[E-6.2] REFLECTED CEILING DEMOLITION
[E-6.3] REFLECTED CEILING DEMOLITION
[E-6.4] REFLECTED CEILING DEMOLITION
[E-6.5] REFLECTED CEILING DEMOLITION
[E-6.6] REFLECTED CEILING DEMOLITION
[E-7.1] ELECTRICAL SINGLE LINE
[E-9.1] ELECTRICAL AND
[E-9.2] ELECTRICAL AND
[E-9.3] ELECTRICAL AND
[E-9.4] ELECTRICAL AND
[E-9.5] ELECTRICAL AND
S Specs 3
Div 12 — Furnishings 1
12 13 14 – Photometrics
Div 85 — Division 85 2
85 87 94 – Spectrum
85 87 95 – Spectrum
A Addenda 0
— no addenda detected
Mech 4sh Plumb 1sh Elec 22sh FP —
  • VRF split-DX cooling system using LG condensing units (e.g., CU-6: model ARUM216CTE5, 575V/3Ph/60Hz, R410A refrigerant) mounted in the mechanical penthouse, each serving multiple indoor fan-coil headers — CU-6 serves 15 VRF headers. … - ISSUED FOR MOCKUP TENDER - 2026-01-30 p.4
  • Extensive hydronic and refrigerant piping valve train including circuit balancing valves, motorized butterfly control valves, pressure-reducing valves, backflow preventers, solenoid valves, and flow meters — indicating a full in-suite and riser piping distribution scope. … - ISSUED FOR MOCKUP TENDER - 2026-01-30 p.1
  • Firestop assemblies required at all pipe sleeve penetrations through floor slabs, achieving a 2-hour F-rating and Class 1 W-rating (watertight under 900 mm / 9 kPa for 72 hours), using Rockwool insulation and fire-resistant waterproof sealant per CAN-S115. … - ISSUED FOR MOCKUP TENDER - 2026-01-30 p.2
  • 1- or 2-hour fire barrier duct wrap required for all ductwork penetrating fire-rated concrete slabs (three-sided wrap with steel anchors and banding) and fire-rated gypsum wallboard assemblies (with silicone sealant and packing material). … - ISSUED FOR MOCKUP TENDER - 2026-01-30 p.3
  • Electrical distribution includes a multi-section 1600A main breaker (MB) panelboard arrangement shown across multiple panels, engineered by HCC Engineering Limited. Elec AC Hotel IFP 2025-11-10 2 p.4