AC Hotel 80 Queen Street East
Drawings
Specs
All
▾
M
Mech
4
[M-302]
75Ø DCW
[M-303]
50Ø DHW
[M-301]
CONTINUATION
[M-305]
65Ø NPW
▾
P
Plumb
1
[P-14]
841 x 1189 ISO A0 SHEET SIZE
▾
E
Elec
22
[E-1.0]
ELECTRICAL LEGEND AND DETAILS
[E-1.1]
ELECTRICAL DETAILS
[E-2.2]
ELECTRICAL PLAN -
[E-2.3]
ELECTRICAL PLAN -
[E-2.4]
ELECTRICAL PLAN -
[E-2.5]
ELECTRICAL PLAN -
[E-2.6]
ELECTRICAL PLAN -
[E-3.2]
REFLECTED CEILING PLAN -
[E-3.3]
REFLECTED CEILING PLAN -
[E-3.4]
REFLECTED CEILING PLAN -
[E-3.6]
REFLECTED CEILING PLAN -
[E-6.2]
REFLECTED CEILING DEMOLITION
[E-6.3]
REFLECTED CEILING DEMOLITION
[E-6.4]
REFLECTED CEILING DEMOLITION
[E-6.5]
REFLECTED CEILING DEMOLITION
[E-6.6]
REFLECTED CEILING DEMOLITION
[E-7.1]
ELECTRICAL SINGLE LINE
[E-9.1]
ELECTRICAL AND
[E-9.2]
ELECTRICAL AND
[E-9.3]
ELECTRICAL AND
[E-9.4]
ELECTRICAL AND
[E-9.5]
ELECTRICAL AND
▾
S
Specs
3
▸
Div 12 — Furnishings
1
12 13 14 – Photometrics
▸
Div 85 — Division 85
2
85 87 94 – Spectrum
85 87 95 – Spectrum
▾
A
Addenda
0
— no addenda detected
MEP Scope
Mech 4sh
Plumb 1sh
Elec 22sh
FP —
Scope Summary
- VRF split-DX cooling system using LG condensing units (e.g., CU-6: model ARUM216CTE5, 575V/3Ph/60Hz, R410A refrigerant) mounted in the mechanical penthouse, each serving multiple indoor fan-coil headers — CU-6 serves 15 VRF headers. … - ISSUED FOR MOCKUP TENDER - 2026-01-30 p.4
- Extensive hydronic and refrigerant piping valve train including circuit balancing valves, motorized butterfly control valves, pressure-reducing valves, backflow preventers, solenoid valves, and flow meters — indicating a full in-suite and riser piping distribution scope. … - ISSUED FOR MOCKUP TENDER - 2026-01-30 p.1
- Firestop assemblies required at all pipe sleeve penetrations through floor slabs, achieving a 2-hour F-rating and Class 1 W-rating (watertight under 900 mm / 9 kPa for 72 hours), using Rockwool insulation and fire-resistant waterproof sealant per CAN-S115. … - ISSUED FOR MOCKUP TENDER - 2026-01-30 p.2
- 1- or 2-hour fire barrier duct wrap required for all ductwork penetrating fire-rated concrete slabs (three-sided wrap with steel anchors and banding) and fire-rated gypsum wallboard assemblies (with silicone sealant and packing material). … - ISSUED FOR MOCKUP TENDER - 2026-01-30 p.3
- Electrical distribution includes a multi-section 1600A main breaker (MB) panelboard arrangement shown across multiple panels, engineered by HCC Engineering Limited. Elec AC Hotel IFP 2025-11-10 2 p.4